{"product_id":"phoenix-battery-commander-bss6102-lithium-ion-charging-and-storage-safe","title":"Phoenix Battery Commander BSS6102 Lithium-Ion Charging and Storage Safe","description":"\u003ccenter\u003e\u003cspan style=\"font-size: x-large;\"\u003e\u003cstrong\u003ePhoenix Battery Commander BSS6102 Lithium-Ion Charging and Storage Safe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/center\u003e\n\u003cp\u003eThe Phoenix Battery Commander BSS6102 is a dedicated lithium-ion battery storage and charging safe built to contain the two most dangerous things a lithium battery can do: catch fire from thermal runaway, and vent flammable gases that feed a fire somewhere else in the facility. For warehouses and distribution centers storing stacks of power tool batteries at shift-end, electric bike and scooter retailers taking in customer batteries for service or overnight charging, construction companies and contractors charging dozens of 18V and 20V tool battery packs for the next workday, facilities handling lithium-ion returns and warranty claims, drone operators and video production houses charging LiPo and Li-ion flight batteries between shoots, laboratories and R\u0026amp;D operations working with prototype battery chemistries, and any operation that stores or charges lithium-ion batteries indoors and is tired of insurance carriers raising premiums (or dropping coverage entirely) over lithium fire exposure, the BSS6102 is engineered specifically to keep a bad cell from becoming a building fire.\u003c\/p\u003e\n\u003cp\u003eThe core capability is that you can charge batteries inside the safe while it is closed. The BSS6102 ships with three Power Distribution Units (PDUs) conforming to UL STD 1363, totaling eighteen outlets across two adjustable shelf levels plus the base, with 2,500 watt-hours of battery capacity rated per level and 7,500 watt-hours total across the safe. Operators plug tool batteries, e-bike packs, or drone batteries into the internal outlets at the end of the day, close and key-lock the door, and leave the batteries charging through the night inside a contained fire-protection envelope. If a cell fails and goes into thermal runaway during that overnight charge window, the automatic door closure seals the safe, the ventilation system manages internal pressure buildup, and the double-wall insulated steel construction contains the fire and heat inside the unit rather than letting it spread to the surrounding building.\u003c\/p\u003e\n\u003cp\u003eFire protection is built on EN 14470-1 (Part 1) tested construction, the European standard specifically written for hazardous-material storage cabinets rather than general-purpose document safes. The 90-minute rating gives first responders time to arrive and extinguish an incident before the fire breaches the cabinet, and the integrated ventilation system exhausts hot gases through a top vent that can optionally be connected to external building ventilation ductwork so the gases exit the building entirely rather than accumulating in the room. For facilities with existing ventilation infrastructure, the external vent connection is the configuration that insurance carriers most commonly ask about during underwriting review.\u003c\/p\u003e\n\u003cp\u003eInside, the BSS6102 provides 7.03 cubic feet of usable storage (35.5 inches tall by 20 inches wide by 15.75 inches deep) organized across two heavy-duty perforated adjustable shelves. The perforated shelving lets airflow move between levels during charging so heat does not pool around a specific pack, and the adjustable mounting lets you size each level to match the actual battery packs you store (one shelf for 18V tool packs, another for larger e-bike or UPS backup batteries, for example). Each shelf supports up to 220 pounds of loaded battery weight, which is ample for typical tool battery or e-bike battery loads.\u003c\/p\u003e\n\u003cp\u003eThe exterior is 48 inches tall by 27.25 inches wide by 28 inches deep, and the 550-pound weight means the BSS6102 is a freight shipment that requires a pallet jack or similar equipment for placement. The key lock is a straightforward access method matched to the typical facility workflow: a single keyholder (operations manager, shift supervisor, or safety officer) controls access, and the key does not need batteries or network connectivity. The multipoint reinforced locking system engages on multiple sides of the door to maintain seal integrity during a fire event.\u003c\/p\u003e\n\u003cp\u003eIf you have questions about the BSS6102, whether its capacity matches your current battery inventory, EN 14470-1 compliance for your insurance underwriting, external ventilation ducting options, or freight and installation requirements for a 550-pound freight shipment, please call us at 800-207-2259.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFire Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTested to EN 14470-1 (Part 1) for 90 minutes of fire protection from external fires\u003c\/li\u003e\n\u003cli\u003eClass 350 1-1\/2-hour fire rating for additional assurance\u003c\/li\u003e\n\u003cli\u003eDouble-wall steel construction with internal fire and heat insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExplosion and Thermal Runaway Containment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt to withstand and contain lithium-ion battery explosions\u003c\/li\u003e\n\u003cli\u003eAutomatic door closure activates during a fire event to seal the safe and limit oxygen feed\u003c\/li\u003e\n\u003cli\u003eIntegrated ventilation ducts manage internal pressure from overheating batteries\u003c\/li\u003e\n\u003cli\u003eTop exit vent allows optional external ventilation connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCharging \u0026amp; Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Power Distribution Units (PDUs) conforming to UL STD 1363\u003c\/li\u003e\n\u003cli\u003eEighteen outlets total for in-safe battery charging\u003c\/li\u003e\n\u003cli\u003e2,500 watt-hours capacity per storage level\u003c\/li\u003e\n\u003cli\u003e7,500 watt-hours total capacity across the safe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterior \u0026amp; Shelving\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo adjustable, perforated heavy-duty shelves (220 lb capacity each)\u003c\/li\u003e\n\u003cli\u003e7.03 cubic feet of usable interior volume\u003c\/li\u003e\n\u003cli\u003ePerforated shelving allows airflow between levels during charging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultipoint reinforced locking system\u003c\/li\u003e\n\u003cli\u003eKey lock access (no batteries or network required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExterior Dimensions: 48.00\" H x 27.25\" W x 28.00\" D\u003c\/li\u003e\n\u003cli\u003eInterior Dimensions: 35.50\" H x 20.00\" W x 15.75\" D\u003c\/li\u003e\n\u003cli\u003eInterior Cubic Feet: 6.47\u003c\/li\u003e\n\u003cli\u003eWeight: 550 lbs\u003c\/li\u003e\n\u003cli\u003eFire Rating: 90 Minutes (EN 14470-1 Part 1) \/ Class 350 1-1\/2-Hour\u003c\/li\u003e\n\u003cli\u003ePower Outlets: 18 (3 PDUs, UL STD 1363)\u003c\/li\u003e\n\u003cli\u003eBattery Capacity per Level: 2,500 Wh\u003c\/li\u003e\n\u003cli\u003eTotal Battery Capacity: 7,500 Wh\u003c\/li\u003e\n\u003cli\u003eShelves: Two adjustable perforated (220 lb capacity each)\u003c\/li\u003e\n\u003cli\u003eLock Type: Key Lock with multipoint reinforced locking system\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eWarranty: 3-Year materials and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWarehouses and distribution centers charging and storing tool battery fleets\u003c\/li\u003e\n\u003cli\u003eElectric bike and electric scooter retailers handling customer batteries\u003c\/li\u003e\n\u003cli\u003eConstruction and contracting firms with overnight charging of 18V\/20V tool battery packs\u003c\/li\u003e\n\u003cli\u003eDrone operators and video production houses with LiPo and Li-ion flight battery inventories\u003c\/li\u003e\n\u003cli\u003eLaboratories, R\u0026amp;D, and manufacturing plants working with lithium-ion cells\u003c\/li\u003e\n\u003cli\u003eFacilities handling lithium-ion returns, warranty claims, or recycling intake\u003c\/li\u003e\n\u003cli\u003eAny operation whose insurance carrier flags lithium-ion exposure as a premium driver\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I actually charge batteries inside this safe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The BSS6102 includes three UL-1363 Power Distribution Units with eighteen total outlets, designed so you can plug in and charge multiple batteries while the safe is closed and locked. The 7,500 watt-hour total capacity rating covers the realistic charging load for typical tool, e-bike, or drone battery fleets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a battery fails and ignites inside the safe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Battery Commander series is engineered to contain fires and explosions from lithium-ion thermal runaway. The automatic door closure seals the safe, the multipoint lock maintains seal integrity, and the ventilation system manages internal pressure. The 90-minute fire rating buys first responders time to arrive before the fire breaches the cabinet, and the top exit vent can optionally duct hot gases outside the building.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this safe help with insurance compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn most cases, yes. Insurance carriers increasingly require documented fire-containment storage for lithium-ion batteries, and EN 14470-1 Part 1 is the specific European hazardous-material-cabinet standard that most carriers reference. We recommend sending the BSS6102 spec sheet to your carrier's underwriter before ordering to confirm the specific documentation your policy requires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs external ventilation required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The integrated internal ventilation system manages pressure on its own. The top exit vent is an optional connection point if your facility has existing ductwork and wants to exhaust gases outside the building entirely. Both configurations are compliant with the EN 14470-1 testing; the external connection is primarily a preference for facilities with sensitive air-quality requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the BSS6102 delivered and installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BSS6102 ships via LTL freight and typically requires liftgate delivery. At 550 pounds, placement requires a pallet jack or four-wheel safe cart, and the unit is not designed for staircase delivery. Call us at 800-207-2259 to confirm delivery requirements for your location.\u003c\/p\u003e","brand":"Phoenix","offers":[{"title":"Default Title","offer_id":41966860009530,"sku":"BSS6102","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1147\/6518\/files\/phoenix-bss6102-1.webp?v=1795590125","url":"https:\/\/www.safeandvaultstore.com\/products\/phoenix-battery-commander-bss6102-lithium-ion-charging-and-storage-safe","provider":"Safe and Vault Store.com","version":"1.0","type":"link"}